Fig. 13.

Download original image
Fig. 13. Fractured metal framework in case 3. (A) Fracture at retentive arm in maxillary removable partial denture (#26), (B) Fracutre at minor connector and rest in mandibular removable partial denture (#46).
J Dent Rehabil Appl Sci 2021;37:39-47 https://doi.org/10.14368/jdras.2021.37.1.39