Journal of Dental Rehabilitation and Applied Science:eISSN 2384-4272 pISSN 2384-4353

Table. 2.

Table. 2.

Improvement comparison after tooth preparation using three self-assessment methods for non-functional cusp slope

AssessmentVisualDigitalPutty index
Reduction error value (Mean, mm)
Before0.3262 ± 0.31320.3997 ± 0.37500.3158 ± 0.3178
After0.4410 ± 0.27260.3526 ± 0.26820.3004 ± 0.2435
P0.03*0.940.94

P < 0.05; Wilcoxon signed rank test.

J Dent Rehabil Appl Sci 2019;35:220-7 https://doi.org/10.14368/jdras.2019.35.4.220